KYODO INTERNATIONAL INC./Japan

Japanese
Contact
  1. KYODO INTERNATIONAL INC./Japan
  2. Biotechnology
  3. Biospherix Oxigen Controller

Biospherix Oxigen Controller

New proposal for hyperoxic/hypoxic experiment

The device to produce environment with hyperoxia or hypoxia
for cell culture and experiment by small animals.

Oxygen Controller ProOx110
  • Control range of oxygen tension 0.1 to 99.9%
  • Reduce gas consumption
  • Control oxygen tension inside various chambers

<Cell culture> I want to make inside of incubator be in hyperoxia/hypoxia condition

By only adding oxygen controller ProOx110, you can control oxygen tension inside existing CO2 incubator

It is economical solution as you can use incubator you already have without preparing extra space.

In case of use of high capacity incubator, please use oxygen controller ProOx360 which is designed for large volume.

Required devices/equipment
ProOx110
CO2incubator, Gas cylinder, gas regulator for low pressure etc. are also necessary.

<Cell culture> I want to make part of incubator in hyperoxia/hypoxia and control oxygen tension in more precise manner

By using chamber, it is possible to minimize volume to be controlled. It leads to reduction of gas usage and more precise tension control. Especially recommended in case less than 1% oxygen control is required.

It is possible to execute multiple protocols by installing multiple C-Chamber inside incubator.

In case it is necessary to control CO2 inside C-Chamber, please use ProCO2, concurrently.
CO2 control range is 0.1 to 20.0%.

Required devices/equipment
ProOx110 / ProCO2 / C-Chamber
CO2 incubator, Gas cylinder, gas regulator for low pressure etc. are also necessary.
About chamber

By using chamber, it is possible to reduce gas consumption and provide more precise gas tension control.

About Chamber
  • Small volume, Reduce gas consumption
  • Robust, Less maintenance
  • Doors with Magnetic sealing
  • With tray for humidification
4 sizes are available (W×D×H)
  • C-174 35.6×30.9×14.7cm
  • C-274 35.6×30.9×16.6cm
  • C-374 35.6×30.9×21.7cm
  • C-474 35.6×30.9×26.8cm

It is still possible to use your own chamber depends on airtightness of the chamber.

<Cell culture> I want to change oxygen tension constantly

In case of constant ascent/descent of oxygen tension, OxyCycler is recommended.

It is possible to control 2 sets of C-Chamber via attached PC.

Gas tension can be automatically ascent/descent depend on lapsed time.

Required devices/equipment
OxyCycler C42 / C-Chamber
CO2 incubator, Gas cylinder, gas regulator for low pressure etc. are also necessary.

<Cell culture> I want to execute long-term experiment of cell culture in stable oxygen tension environment without exposure to air.

During operation for medium exchange and drug dosing, the environment is exposed in the air due to tentative pulling out cultured cell from incubator.

In case long-term stable culture environment is necessary, usage of C-Shuttle and Xvivo are recommended.

  1. Operation
    Create gas environment as same as C-Chamber by attached control unit to C-Shuttle. It enables operation within C-Shuttle without exposure to the air.
  2. Transportation
    It is possible to remove sensor and gas tube from chamber easily. It enables transportation in maintained gas tension without exposure to the air.
  3. Incubation
    Set C-Chamber inside incubator and control gas in C-Chamber by ProOx and ProCO2
Required devices/equipment
OxyCycler C42 / ProOx110 / ProCO2 / C-Chamber
CO2 incubator, Gas cylinder, gas regulator for low pressure etc. are also necessary.
Xvivo Workstation

A glove box incubator system which enables operation and incubation without changing gas environment.

A series of incubation experiment can be executed without exposure to the air.

Xvivo Workstation »

<Experiment by small animals> I want to execute culture experiment of small animals in hyperoxia/hypoxia environment

By using chamber, gas consumption is reduced and more precise gas tension control is possible.


Required devices/equipment
ProOx110 / Animal Chamber
Gas cylinder, gas regulator for low pressure etc. are also necessary.
About Chamber
  • Maintain adequate humidity for small animals
  • With fan for gas agitation
  • Easy to clean
  • Made by Polypropylene (Doors are made by Acrylic)
Parts number and size Inner dimension (W×D×Hcm)
  • A-15274-P 38.1×50.8×50.8cm
  • A-30274-P 76.2×50.8× 50.8cm
  • A-66274-P 167.6×50.8×50.8cm

It is possible to substitute wardrobe for animal chamber.

<Experiment by small animals> I want to change oxygen tension constantly

In case ascent/descent oxygen tension in accordance with lapsed time, usage of OxyCycler is recommended.

It is possible to control 4 sets of C-Chamber via attached PC.

Gas tension can be automatically ascent/descent depend on lapsed time.

Required devices/equipment
OxyCycler A84 / Animal Chamber
Gas cylinder, gas regulator for low pressure etc. are also necessary.


Biospherix Ltd. (USA)
Inquiry about Bio products and services
TEL)+81-044-853-2958 (Did)
FAX)+81-044-854-1979
KYODO INTERNATIONAL INC.
2-10-9 Miyazaki,
Miyamae-ku, Kawasaki-shi,
Kanagawa-ken, 216-0033,
Japan
Back to Top

Biotechnology

[Devices and Reagents for Bioresearch]

  • Nucleic Acid
  • Cell Cultivation / Imaging
  • Protein, Organic

[Biotechnology applied products]

KYODO INTERNATIONAL INC.
2-10-9 Miyazaki,
Miyamae-ku, Kawasaki-shi,
Kanagawa-ken, 216-0033,
Japan
TEL)+81-044-853-2958 (Did)
FAX)+81-044-854-1979
Inquiry about Bio products and services
Copyright © KYODO INTERNATIONAL,INC.
all rights reserved.
Company logos and product names on this website
are registered or unregistered trademark.
Contact us for request of usage of illustrations,
photos and copies on this website.